Fetal dose
Fetal dose estimates the radiation dose absorbed by fetuses during Computed Tomography (CT) imaging of pregnant patients for quantitative fetal dose assessment.
Key Features:
- Monte Carlo simulations: Conducted 750 Monte Carlo (MC) simulations using phantoms representing pregnant patients at various gestational stages to generate vendor-independent dose distributions.
- CTDI validation: Validated the MC code against Computed Tomography Dose Index (CTDI) measurements from two CT scanners, achieving an average error of 4%.
- Algorithm development: Developed a computational algorithm to estimate fetal doses based on parameters such as body region and exposure settings using validated simulations.
- Clinical validation: Validated the algorithm with patient-specific MC simulations using CT data from 29 pregnant patients (gestational ages 8–35 weeks), reporting an average error of 11% and outperforming existing commercially available software.
- Maternal size correlation: Provides quantitative assessment of the relationship between maternal body size (e.g., abdominal perimeter) and fetal dose for dose–response analyses.
Scientific Applications:
- Fetal dose estimation during CT: Generation of vendor-independent quantitative fetal dose estimates from CT exposure parameters.
- Model validation and benchmarking: Validation of MC-based dose models against CTDI measurements and patient-specific simulations for benchmarking.
- Dose–body size analyses: Investigation of the correlation between maternal body size (abdominal perimeter) and fetal radiation dose to inform risk assessment and management.
Methodology:
Performed 750 Monte Carlo simulations with pregnant patient phantoms across gestational stages to produce vendor-independent dose distributions; validated MC code against CTDI measurements from two CT scanners (average error 4%); developed an algorithm to estimate fetal dose from body region and exposure settings using the validated simulations; and validated the algorithm with patient-specific MC simulations from CT data of 29 pregnant patients (8–35 weeks) with an average error of 11%.
Topics
Details
- Tool Type:
- web application
- Added:
- 1/18/2021
- Last Updated:
- 3/10/2021
Operations
Publications
Saltybaeva N, Platon A, Poletti P, Hinzpeter R, Merce MS, Alkadhi H. Radiation Dose to the Fetus From Computed Tomography of Pregnant Patients—Development and Validation of a Web-Based Tool. Investigative Radiology. 2020;55(12):762-768. doi:10.1097/rli.0000000000000701. PMID:32604386.