xcms
xcms processes and visualizes chromatographically separated mass spectrometry data to enable high-throughput, untargeted analyte profiling in LC-MS metabolomics.
Key Features:
- File format support: Import of AIA/ANDI NetCDF, mzXML, mzData and mzML file formats for LC-MS data analysis.
- Chromatographic processing and visualization: Processing and visualization of chromatographically separated mass spectral data, including single-spectra datasets.
- Gap correction for mass calibration switching: A method to correct gaps that occur when manufacturers' mass calibration systems switch between analyte and standard reference compounds during analysis.
- Peak detection: Enhanced peak detection methods tailored to LC-MS metabolomics datasets.
- Quantification and intensity recovery: Procedures to improve quantification and recover expected numbers of peaks and accurate intensity distributions in metabolomics data.
- Untargeted, high-throughput profiling: Support for untargeted analyte profiling in high-throughput LC-MS experiments.
Scientific Applications:
- Untargeted metabolomics: Analysis and interpretation of metabolomics datasets to detect and quantify metabolites without prior targeting.
- Global molecular profiling: Comprehensive molecular profiling of samples using LC-MS-derived mass spectral data.
- LC-MS experiment processing: Processing and correction of LC-MS data for improved peak recovery and intensity distribution accuracy.
- High-throughput analyte profiling: Large-scale untargeted analyte detection and quantification across many samples.
Methodology:
Import AIA/ANDI NetCDF, mzXML, mzData and mzML files; process and visualize chromatographically separated mass spectral data; correct gaps caused by manufacturers' mass calibration switching between analyte and standard reference compounds; perform peak detection and quantification to recover expected peak counts and accurate intensity distributions.
Topics
Collections
Details
- License:
- GPL-2.0
- Maturity:
- Mature
- Tool Type:
- command-line tool, library, web application
- Operating Systems:
- Windows, Linux, Mac
- Programming Languages:
- R
- Added:
- 1/17/2017
- Last Updated:
- 11/5/2025
Operations
Data Inputs & Outputs
Chromatographic alignment
Chromatogram visualisation
Inputs
Outputs
Publications
Benton HP, Want EJ, Ebbels TMD. Correction of mass calibration gaps in liquid chromatography–mass spectrometry metabolomics data. Bioinformatics. 2010;26(19):2488-2489. doi:10.1093/bioinformatics/btq441. PMID:20671148.